发布于 2026年8月25日 · 我们于 2026年8月31日 确认该职位仍然有效
£ 250 – £ 750 (每个项目)
I have designed a small 6 × 6.5 m outbuilding that sits on 650 mm brick walls with a 150 mm cavity of Thermalite blocks and facing brick. Above the masonry I’m installing an oak-framed storey—sill and eaves beams on 200*200 mm studs—then four steel columns that carry a 4 × 2 m roof lantern within a flat roof. Before I place any orders, I’d like a qualified structural engineer to verify the overall load-bearing capacity of the scheme. The review should concentrate on structural integrity, general material selection, and specifically cover: • Brick cavity walls • The oak-framed superstructure • The four steel columns supporting the lantern and flat roof Please analyse the current member sizes, connections, and bearing details, flag any overstressed elements, and propose practical modifications if required. A short calculation report (PDF) plus annotated sketches or mark-ups that I can pass to Building Control will be the expected deliverables. I can supply layout drawings and sections in DWG or PDF as soon as we start.